DSC-S85 SERVICE MANUAL US Model Canadian Model Level 2 AEP Model UK Model E Model Ver 1.1 2001. 08 Hong Kong Model Australian Model Chinese Model Korea Model Tourist Model Japanese Model Differences Manual This Service Manual covers only differences from DSC-S75 (Level 2). In performing repair, refer to DSC-S75 Service Manual (Level 2) (9-929-891-32) as well as this manual. • Main differences: CCD imager changed (3.4 M pixels t 4.0 M pixels) (SEE PAGE ss): Pages on the original service manual. : Pages on this service manual. & : Points added parts. ! : Points deleted parts. - : Points changed ...
Author: 阿由葉 Shared: 8/19/19
Downloads: 2233 Views: 4626

Content

DSC-S85 SERVICE MANUAL US Model Canadian Model Level 2 AEP Model UK Model E Model

Ver 1.1 2001. 08 Hong Kong Model

Australian Model Chinese Model Korea Model Tourist Model Japanese Model Differences Manual

This Service Manual covers only differences from DSC-S75 (Level 2). In performing repair, refer to DSC-S75 Service Manual (Level 2) (9-929-891-32) as well as this manual. • Main differences: CCD imager changed (3.4 M pixels t 4.0 M pixels) (SEE PAGE ss): Pages on the original service manual. : Pages on this service manual. & : Points added parts. ! : Points deleted parts. - : Points changed parts.

DIGITAL STILL CAMERA

,

SPECIFICATIONS System Output connector General AC-L10A/B/C NP-FM50 battery pack

Image device A/V OUT (Monaural) Used battery pack AC power adaptor Used battery 8.98 mm (1/1.8 type) Minijack NP-FM50 Power requirements Lithium ion ba ttery color CCD Video: 1 Vp-p, 75 Ω Power requirements 100 to 240 V AC, 50/60 Hz Maximum voltage unbalanced, sync negative Lens 7.2 V Rated output voltage DC 8.4 V Audio: 327 mV (at a 47 kΩ 3× zoom lens Power consumption DC 8.4 V, 1.5 A in operating Nominal voltage load) f = 7 – 21 mm (9/32 – 27/32 (during recording) mode DC 7.2 V Output impedance: 2.2 kΩ inches) 3.0 W Operation temperature Capacity USB jack (34 – 102 mm (1 3/8 – 4 1/8 Operation temperature 0°C to 40°C (32°F to 104°F) 8.5 Wh (1 180 mAh) mini-B inches) when converted into a 0°C to 40°C Storage temperature 35 mm still camera) External flash jack (32°F to 104°F) –20°C to +60°C Accessories F = 2.0 – 2.5 Minijack Storage temperature (–4°F to +140°F ) A/V connecting cable (1) Exposure control LCD screen –20°C to +60°C NP-FM50 battery pack (1) Maximum dimensions (–4°F to +140°F) AC-L10A AC power adaptor Automatic exposure, Shutter 125×39×62 mm (1) speed priority, Aperture Used LCD panel Maximum dimensions 4.6 cm (1.8 type) TFT (Thin (5×1 9/16×2 1/2 inches) Power cord (1) priority, Manual exposure 117×71×64 mm Film Transistor active matrix) (w/h/d) USB cable (1) White balance (4 5/8×2 7/8×2 5/8 inches) drive Mass Lens cap (1) Automatic, Indoor, Outdoor, (w/h/d) Total number of dots Approx. 280 g (10 oz) Lens cap strap (1)One-push Mass 123 200 (560×220) dots Shoulder strap (1) Data system Approx. 462 g (1 lb) “Memory Stick” (16 MB) (1) Movie: MPEG1 (including battery pack NP- CD-ROM (USB driver SPVD- Still: JPEG, GIF (in TEXT FM50, “Memory Stick,” 004) (1) mode, Clip Motion), TIFF shoulder strap and lens cap Operating Instructions (1) Audio with still image: etc.) MPEG1 (Monaural) Built-in microphone Design and specifications are Recording medium Electret condenser microphone subject to change without “Memory Stick” Built-in speaker notice. Flash Dynamic speaker Recommended recording distance (ISO is set to AUTO): 0.3 m to 3.0 m (11 7/8 inches to 9 feet 10 1/8 inches) – 2 –,

Ver. 1.1 2001. 08 TABLE OF CONTENTS

Section Title Page 5. ADJUSTMENTS 5-1. Camera Section Adjustment ... 4 1-2. Initialization of B, D, E, F, 7, 9 Page Data ... 4 1-2-1. Initialization of D Page Data ... 4 1. Initializing D Page Data ... 4 1-2-2. Initialization of B, E, F, 7, 9 Page Data ... 4 1. Initializing B, E, F, 7, 9 Page Data ... 4 5. F Page Table ... 4 1-4. Camera System Adjustments ... 6 1. Flange Back Adjustment (Using the Minipattern Box) ... 7 2. Flange Back Adjustment (Using the Flange Back Adjustment Chart) ... 8 3. Flange Back Check ... 9 4. Picture Frame Setting ... 10 5. F No. Standard Data Input ... 11 6. Mechanical Shutter Adjustment ... 11 7. Light Level Adjustment ... 12 8. Mixed Color Cancel Adjustment ... 12 9. Auto White Balance Standard Data Input ... 13 10. Auto White Balance Adjustment ... 14 11. Smear Compensation Adjustment ... 15 12. Color Reproduction Adjustment ... 16 13. Color Reproduction Check ... 17 14. Auto White Balance Check ... 18 15. CCD White Defect Compensation ... 19 16. CCD Black Defect Compensation ... 20 17. Strobe White Balance Adjustment ... 21 6. REPAIR PARTS LIST 6-1. Exploded Views ... 22 6-1-1. Main Section ... 22 6-1-2. Cabinet (Front) Block Assembly ... 22 6-1-3. Lens Block Assembly ... 22 6-1-4. Cabinet (Rear) Block Assembly ... 22 6-2. Electrical Parts List ... 23 – 3 –,

DSC-S85 SECTION 5 Ver. 1.1 2001. 08 ADJUSTMENTS

5-1. CAMERA SECTION ADJUSTMENT 1-2. INITIALIZATION OF B, D, E, F, 7, 9 PAGE DATA 5. F Page Table 1-2-1. Initialization of D Page Data Note 1: Fixed data-1: Initialized data. 1. Initializing D Page Data (Refer to “1.Initializing of B, E, F, 7, 9 Page Data”) Note: If the D page data has been initialized, the following Note 2: Fixed data-2: Modified data. adjustments need to be performed again. (Refer to “2.Modification of B, E, F, 7, 9 Page Data”) 1) Modification of D page data 2) LCD system adjustments Address Initial value Remark 10 to 13 Fixed data-1 (Initialized data) Adjusting page D 14 33 Adjusting Address 10 to EF 15 48 16 DA Initializing Method: 17 DF Order Page Address Data Procedure 18 131001 01 19 C02403 0A 1A 003400 2D 1B 004401 2D Press PAUSE button. 1C 005402 Check the data changes to “01”. 1D 00 Flange back adj. Perform “Modification ofD61E 00page Data”. 1F 00 1-2-2. Initialization of B, E, F, 7, 9 Page Data 20 20 1. Initializing B, E, F, 7, 9 Page Data 21 20 Note: If the B, E, F, 7, 9 Page data has been initialized, 22 BA “Modification of B, E, F, 7, 9 Page Data” and following adjustments need to be performed again. 23 46 1) Modification of B, E, F, 7, 9 page data 24 0A 2) Video system adjustments 25 00 3) Camera system adjustments 26 85 Adjusting page F 27 B0 Light level adj. Adjusting Address 10 to FF 28 94 Adjusting page E 29 00 Adjusting Address 00 to FF 2A 00 Adjusting page B 2B 00 F No. standard data input Adjusting Address 00 to FF 2C 00 Adjusting page 7 2D 00 Adjusting Address 00 to FF 2E to 39 Fixed data-1 (Initialized data) Adjusting page 9 3A 2F Adjusting Address 00 to FF 3B 37 Auto white balance standard data 3C 40 input Initializing Method: 3D D0 Order Page Address Data Procedure 3E Fixed data-1 (Initialized data) 1 0 01 01 3F B5 Auto white balance adj. 2 6 03 0A 40 433600 2D 41 034601 2D Press PAUSE button. 42 E95602 Check the data changes to “01”. 43 63 Perform “Modification of B, 6 44 83 E, F, 7, 9 page Data”. Color reproduction adj. 45 D5 46 FE 47 73 48 45 – 4 –,

Ver. 1.1 2001. 08

Address Initial value Remark Address Initial value Remark 49 to 4C Fixed data-1 (Initialized data) 8B 00 4D 28 Strobe white balance adj. 8C 00 4E 6E 8D 00 4F to 58 Fixed data-1 (Initialized data) 8E 00 59 00 Auto white balance standard data input 8F 00 5A 14 Mechanical shutter adj. 90 00 5B Fixed data-1 (Initialized data) 91 00 5C 63 92 00 5D 83 Color reproduction adj. 93 00 Flange back adj. 5E 03 94 00 5F E9 95 00 60 to 63 Fixed data-1 (Initialized data) 96 00 64 10 Strobe white balance adj. 97 00 65 to 68 Fixed data-1 (Initialized data) 98 00 69 02 99 00 6A 79 Strobe white balance adj. 9A 00 6B F8 9B 00 6C 10 9C Fixed data-1 (Initialized data) 6D 05 9D 16 Smear compensation adj. 6E 09 9E 1C 6F B5 9F Fixed data-1 (Initialized data) 70 07 A0 00 71 C4 A1 00 72 07 Mixed color cancel adj.A2 00 73 48 A3 00 74 06 A4 to A8 Fixed data-1 (Initialized data) 75 CB Mechanical shutter adj. A9 2C Auto white balance adj. 76 01 AA 06 77 01 AB to D3 Fixed data-1 (Initialized data) 78 01 D4 80 79 01 D5 9E 7A 01 D6 94 Mechanical shutter adj. 7B 2C D7 94 7C 3A D8 94 7D 2E D9 to FF Fixed data-1 (Initialized data) 7E 40 7F 40 80 00 Auto white balance adj. 81 to 86 Fixed data-1 (Initialized data) 87 FF 88 00 Flange back adj. 89 00 8A 00 – 5 –,

Ver. 1.1 2001. 08

1-4. CAMERA SYSTEM ADJUSTMENTS Before perform the camera system adjustments, check that the specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat- isfied. Note: For “CAMERA SYSTEM ADJUSTMENTS”, perform in order of item numbers. Data setting during camera system adjustments Perform the following data setting before the camera system ad- justments. Menu setting: 1) VIDEO OUT of SET UP menu... NTSC (NTSC mode) (This adjustment must be performed in NTSC mode, so don't set the menu setting to “PAL”) Data setting method: Order Page Address Data Procedure1001 012D10 80 Press PAUSE button. Check the bit values of bit3, 3 2 10 bit4 and bit5 are “1”. (Note 1, 2) 4 D 11 40 Press PAUSE button. 5 D 10 81 Press PAUSE button. Check the data changes to56C1 “02”. 6 4 06 01766C 01 8 Wait for 1 second. 9 B 75 00 Press PAUSE button. Note 1: For the bit values, refer to “5-2. SERVICE MODE”, “2-3. 2. Bit value discrimination”. Note 2: In case of wrong data, select page: 2, address: 0A and set data: 02. Set the adjusting remote commander to normal LANC, and the power will be turned off and on automatically. Wait for more than 0.167 second after the power on, and set the adjusting remote commander to the service LANC. Then, retry from the step 1. Note 3: Repeat the “Data setting method”, if the power was turned off and on during the “CAMERA SYSTEM ADJUST- MENTS”. After completing the camera system adjustments, release the data setting: Order Page Address Data Procedure1406 00266C 003B75 10 Press PAUSE button. 4 D 11 00 Press PAUSE button. 5 D 10 00 Press PAUSE button. 6 0 01 00 – 6 –, 1. Flange Back Adjustment (Using the minipattern box) Specified voltage: The specified voltage varies according to the The flange back of inner focus lens is adjusted automatically. If minipattern box, so adjustment the power sup- shifted, the auto focus is disordered. ply output voltage to the specified voltage writ- ten on the sheet which is supplied with the mini- Mode CAMERA pattern box. Subject Siemens star chart with ND filter Below 3 cm for minipattern box (Note 1) Minipattern box Measurement Point Check operation on the LCD Measuring Instrument screen Camera Adjustment Page F Camera Adjustment Address 14 to 25, 87 to 9B table Note 1: Dark Siemens star chart. Regulated power supply Note 2: Check that the data of page: 6, address: 02 is “00”. Output voltage : Specified voltage ± 0.01 Vdc If not, turn the power of unit OFF/ON. Output current : more than 3.5 A Preparations before adjustments: 1) The minipattern box is installed as shown in the following fig- Red (+) ure. Note 3: The attachment lenses are not used. Black (–) Note 4: Take care not to hit the mini-pattern box when Yellow (SENS +) extending the lens. 2) Install the minipattern box so that the distance between it and White (SENS –) Need not connected the front of lens of camera is less than 3 cm. Black (GND) 3) Make the height of minipattern box and the camera equal. 4) Check the output voltage of the regulated power supply is the Fig. 5-1-13 specified voltage ± 0.01 Vdc. 5) Check that the center of Siemens star chart meets the center of Adjusting method: shot image screen with the zoom lens at TELE end and WIDE end respectively. Order Page Address Data Procedure 6) Check that the data on page: F, address: 14 to 25 and 87 to 9B1001 01 are initial value (See table below). Perform “Data setting during Address Data Address Data Address Data 2 camera system adjustments”. 14 33 21 20 8F 00 (Refer to page 5-14) 15 48 22 BA 90 003601 13 Press PAUSE button. 16 DA 23 46 91 004601 27 Press PAUSE button. (Note 5) 17 DF 24 0A 92 005602 Check the data changes to “01”. 18 13 25 00 93 006F87 Check the data changes to “00”. 19 C0 87 FF 94 00 Note 5: The adjustment data will be automatically input to page: F, address: 14 to 25 and 87 to 9B. 1A 00 88 00 95 00 1B 00 89 00 96 00 Processing after Completing Adjustment: 1C 00 8A 00 97 00 Order Page Address Data Procedure 1D 00 8B 00 98 001601 00 Press PAUSE button. 1E 00 8C 00 99 00 Release the data setting 1F 00 8D 00 9A 00 2 performed at step 2. (Refer to 20 20 8E 00 9B 00 page 5-14) 3 0 01 00 4 Perform“Flange Back Check”. – 7 –, 2. Flange Back Adjustment Adjusting method: (Using the flange back adjustment chart) Order Page Address Data Procedure The flange back of inner focus lens is adjusted automatically. If shifted, the auto focus is disordered. 1 0 01 01 Perform “Data setting during Mode CAMERA 2 camera system adjustments”. Subject Flange back adjustment chart (Refer to page 5-14) (2.0 m from the front of the lens) 3 6 01 13 Press PAUSE button. (Luminance: 300 to 400 lux) 4 6 01 15 Press PAUSE button. (Note 2) Measurement Point Check operation on the LCD5602 Check the data changes to “01”. Measuring Instrument screen6F87 Check the data changes to “00”. Adjustment Page F Note 2: The adjustment data will be automatically input to Adjustment Address 14 to 25, 87 to 9B page: F, address: 14 to 25 and 87 to 9B. Note 1: Check that the data of page: 6, address: 02 is “00”. If not, turn the power of unit OFF/ON. Processing after Completing Adjustment: Order Page Address Data Procedure Preparations before adjustments: 1) Place the Flange back adjustment chart 2.0 m from the front1601 00 Press PAUSE button. of the lens. Release the data setting 2) Check that the center of Flange back adjustment chart meets 2 performed at step 2. the center of shot image screen with the zoom lens at TELE (Refer to page 5-14) end and WIDE end respectively. 3 0 01 00 3) Check that the data on page: F, address: 14 to 25 and 87 to 9B are initial value (See table below). 4 Perform“Flange Back Check”. Address Data Address Data Address Data 14 33 21 20 8F 00 15 48 22 BA 90 00 16 DA 23 46 91 00 17 DF 24 0A 92 00 18 13 25 00 93 00 19 C0 87 FF 94 00 1A 00 88 00 95 00 1B 00 89 00 96 00 1C 00 8A 00 97 00 1D 00 8B 00 98 00 1E 00 8C 00 99 00 1F 00 8D 00 9A 00 20 20 8E 00 9B 00 – 8 –, 3. Flange Back Check Mode CAMERA Subject Siemens star chart (1.0 m from the front of the lens) (Luminance: 200 to 400 lux) Measurement Point Check operation on the LCD Measuring Instrument screen Specified value Focused at the TELE end and WIDE end Checking method: Order Page Address Data Procedure Place the Siemens star 1.0 m from the front of the lens. To open the IRIS , decrease 1 the luminous intensity to the Siemens star up to a point before noise appear on the image. 2 0 01 01 Perform “Data setting during 3 camera system adjustments”. (Refer to page 5-14) Shoot the Siemens star chart with the zoom TELE end. 4 At this time, the center of Siemens star chart should be in the center of the LCD screen. Check that the lens is focused. 6 6 2C 01 While observe the LCD 7 screen, change the zoom to the WIDE end and check that the lens is focused. Processing after Completing Adjustment: Order Page Address Data Procedure162C 00 Release the data setting 2 performed at step 3. (Refer to page 5-14) 3 0 01 00 – 9 –, 4. Picture Frame Setting How to reset the zoom and focus when they deviated: Mode CAMERA Order Page Address Data Procedure Subject Color bar chart162C 01 (Color reproduction adjustment2690 00 frame with the zoom lens at3691 00 WIDE end) 4 6 92 YL (Note 2) Measurement Point Video terminal of A/V OUT jackΩ5693 YH (Note 2)(75 terminated) 6 6 01 79 Press PAUSE button. Measuring Instrument Oscilloscope and TV monitor7607 Check the data changes to “01”. Specified Value A=B, C=D, E=F8601 00 Press PAUSE button. Note 1: Displayed data of the page 1 of adjusting remote com- mander. Note 2: The data noted down at step 9 of “Setting method”. 1:XX:XX YL data Check on the oscilloscope YH data 1. Horizontal period Switch setting: 1) FOCUS ... AF (AUTO FOCUS) A=B C=D Setting method: B C Order Page Address Data ProcedureAD1001 01 Perform “Data setting during 2 camera system adjustments”. (Refer to page 5-14) Shoot the color bar chart with the zoom WIDE end. Enter the output of VIDEO 4 OUT to the TV monitor, and move to the position as shown in Fig. 5-1-16. Horizontal width of one color (B, C) and that of black 5 (A, D) on the color bar chart should be same. (See Fig. 5- 1-14) Fig. 5-1-14 With vertical width of black (E, F) set in same, the color 2. Vertical period 6 bar chart should come to the center of TV monitor. E E=F F (See Fig. 5-1-15) Check that the color bar on the TV monitor is focused. 8 0 03 22 Note down the YH and YLV91data. (Note 1) Fig. 5-1-15 Processing after Completing Adjustment: Check on the TV monitor Order Page Address Data Procedure1003 00 Release the data setting 2 performed at step 2 . (Refer to page 5-14) 3 0 01 00 Color bar chart picture frame TV monitor picture frame Fig. 5-1-16 – 10 –, 5. F No. Standard Data Input 6. Mechanical Shutter Adjustment Compensate the unevenness of the iris meter sensitivity. Adjust the period which the mechanical shutter is closed, and com- pensate the exposure. Mode CAMERA Subject Clear chart Mode CAMERA (Color reproduction adjustment Subject Clear chart frame with the zoom lens at WIDE (Color reproduction adjustment end) frame with the zoom lens at WIDE Adjustment Page F end) Adjustment Address 29 to 2D Adjustment Page F Note 1: Check that the data of page: 6, address: 02 is “00”. Adjustment Address 5A, 6C to 7F, D4 to D8 If not, turn the power of unit OFF/ON. Note 1: Check that the data of page: 6, address: 02 is “00”. Note 2: Refer to “Picture Frame Setting” for YH and YL. If not, turn the power of unit OFF/ON. Note 2: Refer to “Picture Frame Setting” for YH and YL. Adjusting method: Order Page Address Data Procedure Adjusting method: 1 0 01 01 Order Page Address Data Procedure Perform “Data setting during1001 01 2 camera system adjustments”. Perform “Data setting during (Refer to page 5-14) 2 camera system adjustments”. 3 6 2C 01 (Refer to page 5-14) 4 6 90 00362C 015691 004690 006692 YL (Note 2) 5 6 91 007693 YH (Note 2) 6 6 92 YL (Note 2) 8 6 01 79 Press PAUSE button. 7 6 93 YH (Note 2) 9 6 07 Check the data changes to “01”. 8 6 01 79 Press PAUSE button. 10 6 01 00 Press PAUSE button. 9 6 07 Check the data changes to “01”. 11 6 01 BB Press PAUSE button. (Note 3) 10 6 01 00 Press PAUSE button. 12 6 02 Check the data changes to “01”. 11 6 01 AD Press PAUSE button. (Note 3) Note 3: The adjustment data will be automatically input to page: 12 6 02 Check the data changes to “01”. F, address: 29 to 2D. 13 6 AB Check the data changes to “00”. Processing after Completing Adjustment: Note 3: The adjustment data will be automatically input to page: F, address: 5A, 6C to 7F and D4 to D8. Order Page Address Data Procedure1601 00 Press PAUSE button. Processing after Completing Adjustment: 2 6 2C 00 Order Page Address Data Procedure3692 001601 00 Press PAUSE button. 4 6 93 00262C 00 Release the data setting3692 00 5 performed at step 2 . 4 6 93 00 (Refer to page 5-14) Release the data setting6001 00 5 performed at step 2 . (Refer to page 5-14) 6 0 01 00 – 11 –,

Ver. 1.1 2001. 08

7. Light Level Adjustment 8. Mixed Color Cancel Adjustment Adjust the standard LV value. To perform mixed color cancel adjustment based on data of each color in color bar. Mode CAMERA Subject Clear chart Mode CAMERA (Color reproduction adjustment Subject Color bar chart frame with the zoom lens at (Color reproduction adjustment WIDE end) frame with the zoom lens at Measurement Point Displayed data of page: 1 (Note 3) WIDE end) Measuring Instrument Adjusting remote commander Adjustment Page F Adjustment Page F Adjustment Address A0 to A3 Adjustment Address 26 to 28 Note 1: Check that the data of page: 6, address: 02 is “00”. Specified Value AE level: 0FC0 to 1040 If not, turn the power of the unit OFF/ON. Note 2: Refer to “Picture Frame Setting” for YH and YL. Note 1: Check that the data of page: 6, address: 02 is “00”. If not, turn the power of the unit OFF/ON. Adjusting method: Note 2: Refer to “Picture Frame Setting” for YH and YL. Note 3: The right 4 digits of the page: 1 displayed data of the Order Page Address Data Procedure adjusting remote commander. 1 0 01 01 1:XX:XX Perform “Data setting during Displayed data 2 camera system adjustments”. (Refer to page 5-14) Adjusting method: 3 6 2C 01 Order Page Address Data Procedure4690 001001 015691 00 Perform “Data setting during6692 YL (Note 2) 2 camera system adjustments”. (Refer to page 5-14) 7 6 93 YH (Note 2) 3 6 2C 018601 79 Press PAUSE button. 4 6 90 009607 Check the data changes to “01”. 5 6 91 00 10 6 01 00 Press PAUSE button. 6 6 92 YL (Note 2) 11 6 01 D7 Press PAUSE button. 7 6 93 YH (Note 2) 12 6 01 D5 Press PAUSE button. (Note 3) 8 6 01 79 Press PAUSE button. 13 6 02 Check the data changes to “01”. 9 6 07 Check the data changes to “01”. Note 3: The adjustment data will be automatically input to page: F, address: A0 to A3. 10 6 01 00 Press PAUSE button. 11 6 01 0D Press PAUSE button. (Note 4) Processing after Completing Adjustment: 12 6 02 Check the data changes to “01”. Order Page Address Data Procedure 13 0 03 061601 00 Press PAUSE button. Check that the displayed data262C 00 14 1 (Note 3) satisfies the AE level3692 00 specified value. 4 6 93 00 Note 4: The adjustment data will be automatically input to Release the data setting page: F, address: 26 to 28. 5 performed at step 2 . (Refer Processing after Completing Adjustment: to page 5-14) Order Page Address Data Procedure6001 001003 002601 00 Press PAUSE button. 3 6 2C 004692 005693 00 Release the data setting 6 performed atstep 2 . (Refer to page 5-14) 7 0 01 00 – 12 –, 9. Auto White Balance Standard Data Input Adjust the white balance standard data at 3200K. Mode CAMERA Subject Clear chart (Color reproduction adjustment frame with the zoom lens at WIDE end) Adjustment Page F Adjustment Address 3A to 3D, 59 Note 1: Check that the data of page: 6, address: 02 is “00”. If not, turn the power of unit OFF/ON. Note 2: Refer to “Picture Frame Setting” for YH and YL. Note 3: “Auto White Balance Standard Data Input” is available only once after the power is turned on. Turn the power off, then on again if the adjustment is retried. Adjusting method: Order Page Address Data Procedure1001 01 Perform “Data setting during 2 camera system adjustments”. (Refer to page 5-14) 3 6 2C 014690 005691 006692 YL (Note 2) 7 6 93 YH (Note 2) 8 6 01 79 Press PAUSE button. 9 6 07 Check the data changes to “01”. 10 6 01 00 Press PAUSE button. 11 6 01 11 Press PAUSE button. 12 6 01 0B Press PAUSE button. (Note 4) 13 6 02 Check the data changes to “01”. Note 4: The adjustment data will be automatically input to page: F, address: 3A to 3D and 59. Processing after Completing Adjustment: Order Page Address Data Procedure1601 00 Press PAUSE button. 2 6 2C 003692 004693 00 Release the data setting 5 performed at step 2 . (Refer to page 5-14) 6 0 01 00 – 13 –,

Ver. 1.1 2001. 08

10. Auto White Balance Adjustment Order Page Address Data Procedure Adjust to the proper auto white balance output data. If it is not correct, auto white balance and color reproducibility will be poor. Check that the displayed data 19 1 (Note 3) Mode CAMERA satisfies the R ratio specified value. Subject Clear chart (Color reproduction adjustment 20 0 03 05 frame with the zoom lens at Check that the displayed data WIDE end) 21 1 (Note 3) Filter Filter C14 for color temperature satisfies the B ratio specified correction value. Measurement Point Displayed data of page: 1 (Note 3) 22 6 01 00 Press PAUSE button. Measuring Instrument Adjusting remote commander 23 6 01 11 Press PAUSE button. Adjustment Page F 24 6 13 AE Press PAUSE button. Adjustment Address 3F, 40, 80, A9, AA 25 6 01 D3 Press PAUSE button. Specified Value R ratio: 28E0 to 2A20 26 6 02 Check the data changes to “01”. B ratio: 5D60 to 5EA0 Note 5: The adjustment data will be automatically input to Note 1: Check that the data of page: 6, address: 02 is “00”. page: F, address: 3F, 40, 80, A9 and AA. If not, turn the power of unit OFF/ON. Note 2: Refer to “Picture Frame Setting” for YH and YL. Processing after Completing Adjustment: Note 3: The right 4 digits of the page: 1 displayed data of the Order Page Address Data Procedure adjusting remote commander. 1 0 03 00 1:XX:XX Displayed data2601 00 Press PAUSE button. 3 6 13 00 Press PAUSE button. Note 4: “Auto White Balance Adjustment” is available only once462C 00 after the power is turned on. Turn the power off, then on again if the adjustment is retried. 5 6 92 006693 00 Adjusting method: 49 Set the data noted down at Order Page Address Data Procedure7F4A step 13, and press PAUSE 1 Place the C14 filter on the lens. 4B button. 4C2001 01 Release the data setting Perform “Data setting during 8 performed at step 3 . 3 camera system adjustments”. (Refer to page 5-14) (Refer to page 5-14) 9 0 01 00462C 01 Remove the C14 filter on the5690 00 10 lens. 6 6 91 007692 YL (Note 2) 8 6 93 YH (Note 2) 9 6 01 79 Press PAUSE button. 10 6 07 Check the data changes to “01”. 11 6 01 00 Press PAUSE button. 12 6 01 A7 Press PAUSE button. 13 F 4A Note down the data. 4B 4C 49 29 14 F 4A 80 Press PAUSE button. 4B 5E 4C 00 15 6 01 A5 Press PAUSE button. (Note 5) 16 6 02 Check the data changes to “01”. 17 6 01 3F Press PAUSE button. 18 0 03 04 – 14 –, 11. Smear Compensation Adjustment Adjust the smear compensation data from white balance standard data at 3200K. Mode CAMERA Subject Clear chart (Color reproduction adjustment frame with the zoom lens at WIDE end) Adjustment Page F Adjustment Address 9D, 9E Note 1: Check that the data of page: 6, address: 02 is “00”. If not, turn the power of unit OFF/ON. Note 2: Refer to “Picture Frame Setting” for YH and YL. Note 3: “Smear Compensation Adjustment” is available only once after the power is turned on. Turn the power off, then on again if the adjustment is retried. Adjusting method: Order Page Address Data Procedure1001 01 Perform “Data setting during 2 camera system adjustments”. (Refer to page 5-14) 3 6 2C 014690 005691 006692 YL (Note 2) 7 6 93 YH (Note 2) 8 6 01 79 Press PAUSE button. Check the data changes to9607 “01”. 10 6 01 00 Press PAUSE button. 11 6 01 11 Press PAUSE button. 12 6 13 AE Press PAUSE button. 13 6 01 D1 Press PAUSE button. (Note 4) 14 6 02 Check the data changes to “01”. Note 4: The adjustment data will be automatically input to page: F, address: 9D and 9E. Processing after Completing Adjustment: Order Page Address Data Procedure1601 00 Press PAUSE button. 2 6 13 00 Press PAUSE button. 3 6 2C 004692 005693 00 Release the data setting 6 performed at step 2. (Refer to page 5-14) 7 0 01 00 – 15 –,

Ver. 1.1 2001. 08

12. Color Reproduction Adjustment Processing after Completing Adjustment: Adjust the color separation matrix coefficient so that proper color reproduction is produced. Order Page Address Data Procedure1601 00 Press PAUSE button. Mode CAMERA262C 00 Subject Color bar chart3692 00 (Color reproduction adjustment frame with the zoom lens at4693 00 WIDE end) Release the data setting Adjustment Page F performed at step 2 . (Refer to page 5-14) Adjustment Address 41 to 48, 5C to 5F6001 00 Note 1: Check that the data of page: 6, address: 02 is “00”. Perform “Color Reproduc- If not, turn the power of the unit OFF/ON. 7 tion Check”. Note 2: Refer to “Picture Frame Setting” for YH and YL. Note 3: “Color Reproduction Adjustment” is available only once after the power is turned on. Turn the power off, then on again if the adjustment is retried. Adjusting method: Order Page Address Data Procedure1001 01 Perform “Data setting during 2 camera system adjustments”. (Refer to page 5-14) 3 6 2C 014690 005691 006692 YL (Note 2) 7 6 93 YH (Note 2) 8 6 01 79 Press PAUSE button. 9 6 07 Check the data changes to “01”. 10 6 01 00 Press PAUSE button. 11 6 01 AB Press PAUSE button. 12 6 12 80 13 Wait for 1 second. 14 6 12 00 15 Wait for 2 seconds. 16 6 01 A9 Press PAUSE button. (Note 4) 17 6 02 Check the data changes to “01”. Note 4: The adjustment data will be automatically input to page: F, address: 41 to 48 and 5C to 5F. – 16 –,

Ver. 1.1 2001. 08

13. Color Reproduction Check Processing after Completing Adjustment: Mode CAMERA Order Page Address Data Procedure Subject Color bar chart1601 00 Press PAUSE button. (Color reproduction adjustment2610 00 frame with the zoom lens at362C 00 WIDE end) 4 6 92 00 Measurement Point Video terminal of A/V OUT jack5693 00 (75 Ω terminated) Set the data noted down at Measuring Instrument Vectorscope6E52 step 12, and press PAUSE Specified Value All color luminance points button. should settle within each color Release the data setting reproduction frame. 7 performed at step 2 . (Refer Note 1: Check that the data of page: 6, address: 02 is “00”. to page 5-14) If not, turn the power of the unit OFF/ON. Note 2: 8 0 01 00Refer to “Picture Frame Setting” for YH and YL. Adjusting method: Order Page Address Data Procedure1001 01 R-Y Perform “Data setting during 2 camera system adjustments”. (Refer to page 5-14) R MG362C 014690 005691 00 YE6692 YL (Note 2) 7 6 93 YH (Note 2) B-Y8601 79 Press PAUSE button. B9607 Check the data changes to “01”. 10 6 01 00 Press PAUSE button. 11 6 10 01

CY

12 E 52 Note down the data. G 13 E 52 09 Press PAUSE button. Burst position 14 6 01 0F Press PAUSE button. 15 6 12 80 16 Wait for 1 second. Fig. 5-1-17 17 6 12 00 18 Wait for 2 seconds. Check the each color 19 luminance point is in each color reproduction frame. – 17 –,

Ver. 1.1 2001. 08

14. Auto White Balance Check OUTDOOR luminance check Mode CAMERA Place the C14 filter on the20 Subject Clear chart lens. (Color reproduction adjustment 21 E 4B Note down the data. frame with the zoom lens at 22 E 4B 20 Press PAUSE button. WIDE end) 23 6 01 3F Press PAUSE button. Measurement Point Displayed data of Video terminal Check that the center of the of Page: 1 A/V OUT jack Ω 24 white luminance point settles(Note 3) (75 terminated) in the circle shown Measuring Instrument Adjusting remote Vectorscope Fig. 5-1-18 (B). commander Specified Value R ratio: Fig. 5-1-18 Processing after Completing Adjustment: 3E00 to 4200 (A) and (B) B ratio: Order Page Address Data Procedure 3E00 to 42001003 00 Note 1: Check that the data of page: 6, address: 02 is “00”. 2 6 01 00 Press PAUSE button. If not, turn the power of unit OFF/ON. 3 6 2C 00 Note 2: Refer to “Picture Frame Setting” for YH and YL. 4 6 92 00 Note 3: The right 4 digits of the page: 1 displayed data of the adjusting remote commander. 5 6 93 00 1:XX:XX Set the data noted down at Displayed data6E4B step 21, and press PAUSE button. Checking method: Set the data noted down at Order Page Address Data Procedure7E52 step 12, and press PAUSE Check that the lens is not button. covered with either filter. Release the data setting2001 01 8 performed at step 3 . (Refer to page 5-14) Perform “Data setting during 3 camera system adjustments”. 9 0 01 00 (Refer to page 5-14) Remove the C14 filter on the10462C 01 lens. 5 6 90 006691 00 R-Y7692 YL (Note 2) 8 6 93 YH (Note 2) B-Y9601 79 Press PAUSE button. 4 mm 10 6 07 Check the data changes to “01”. 11 6 01 00 Press PAUSE button. 4 mm INDOOR data check (without ND filter) 12 E 52 Note down the data. Fig. 5-1-18 (A) 13 E 52 0E Press PAUSE button. 14 6 01 0F Press PAUSE button. 15 0 03 04 Check that the displayed data 16 R-Y1 (Note 3) satisfied the R ratio specified value. 1 mm 17 0 03 05 B-Y Check that the displayed data 1.5 mm 18 1 (Note 3) satisfied the B ratio 6 mm specified value. INDOOR luminance point check 6 mm Check that the center of the 19 white luminance point within the circle shown Fig. 5-1-18 (A). Fig. 5-1-18 (B) – 18 –,

Ver. 1.1 2001. 08

15. CCD White Defect Compensation Mode CAMERA Subject Not required Measurement Point Displayed data of page: 6, address: 55 Measuring Instrument Adjusting remote commander Adjustment Page 7 Adjustment Address 88 to A3 Note 1: Check that the data of page: 6, address: 02 is “00”. If not, turn the power of unit OFF/ON. Adjusting method: Order Page Address Data Procedure1001 01 Perform “Data setting during 2 camera system adjustments”. (Refer to page 5-14) 3 F DE Note down the data. 4 F DE 1E Press PAUSE button. 5 F E3 Note down the data. 6 F E3 0E Press PAUSE button. 7 6 01 8B Press PAUSE button. (Note 2) 8 6 02 Check the data changes to “01”. Check the data. 9 6 55 00 to 7F: Normal 80 to FF: Defective 10 6 01 00 Press PAUSE button. 11 F DE 0F Press PAUSE button. 12 F E3 60 Press PAUSE button. 13 6 01 87 Press PAUSE button. 14 6 02 Check the data changes to “01”. 15 6 55 Check the data changes to “00”. Note 2: The adjustment data will be automatically input to page: 7, address: 88 to A3. Processing after Completing Adjustment: Order Page Address Data Procedure1601 00 Press PAUSE button. Set the data noted down at2FE3 step 5, and press PAUSE button. Set the data noted down at3FDE step 3, and press PAUSE button. Release the data setting 4 performed at step 2 . (Refer to page 5-14) 5 0 01 00 – 19 –, 16. CCD Black Defect Compensation Processing after Completing Adjustment: Mode CAMERA Order Page Address Data Procedure Subject Clear chart1601 00 Press PAUSE button. (Color reproduction adjustment262C 00 frame) 3 6 30 00 Measurement Point Displayed data of page: 6, 4 6 91 00 address: 55 Set the data noted down at Measuring Instrument Adjusting remote commander5FDF step 3, and press PAUSE Adjustment Page 7 button. Adjustment Address 60 to 87 Release the data setting 6 performed at step 2 . (Refer Note 1: Check that the data of page: 6, address: 02 is “00”. to page 5-14) If not, turn the power of unit OFF/ON. Note 2: Check that there are no dust, no dirt and reflection of the7001 00 clear chart. Note 3: Any subject other than the clear chart should be in the screen. Adjusting method: Order Page Address Data Procedure1001 01 Perform “Data setting during 2 camera system adjustments”. (Refer to page 5-14) 3 F DF Note down the data. 4 F DF 4C Press PAUSE button. 5 6 2C 016690 007691 038692 009693 00 10 6 01 79 Press PAUSE button. 11 6 30 01 12 6 07 Check the data changes to “01”. 13 6 01 8D Press PAUSE button. (Note 4) 14 6 02 Check the data changes to “01”. Check the data. 15 6 55 00 to 0A: Normal 0B to FF: Defective 16 6 01 00 Press PAUSE button. 17 F DF 5A Press PAUSE button. 18 6 01 89 Press PAUSE button. 19 6 02 Check the data changes to “01”. 20 6 55 Check the data changes to “00”. Note 4: The adjustment data will be automatically input to page: 7, address: 60 to 87. – 20 –, 17. Strobe White Balance Adjustment Adjusting method: Adjust the white balance when the strobe light flashed. Order Page Address Data Procedure Mode CAMERA1001 01 Subject Flash adjustment box (Note 3) Perform “Data setting during (1.0 m from the front of the lens) 2 camera system adjustments”. (Refer to page 5-14) Adjustment PageF3690 00 Adjustment Address 4D, 4E, 64, 69 to 6B4691 00 Specified Value Y level data: 60 to 94 (Note 4) R-Y level data: FA to FF or 00 to 065692 FF (Note 5) 6 6 93 FF B-Y level data: FA to FF or 00 to 06762C 01 (Note 5) 8 6 01 79 Press PAUSE button. Note 1: Check that the data of page: 6, address: 02 is “00”. 9 6 07 Check the data changes to “01”. If not, turn the power of unit OFF/ON. 10 6 01 67 Press PAUSE button. Note 2: Perform this adjustment in the Flash adjustment box. Note 3: Refer to “4. Preparing the Flash adjustment box”. (See Check the flashing of strobe11 page 5-7) light. Note 4: Displayed data of page: F, address: 64, of the adjusting 12 6 02 Check the data changes to “01”. remote commander. 13 6 01 00 Press PAUSE button. F:XX:64 Y level data 14 6 01 67 Press PAUSE button. Note 5: The right four digits of the page: 1 displayed data of the Check the flashing of strobe15 adjusting remote commander. light. 1:XX:XX 16 6 02 Check the data changes to “01”. B-Y level data R-Y level data 17 6 01 00 Press PAUSE button. Note 6: “Strobe White Balance Adjustment” is available only 18 7 03 05 Press PAUSE button. once after the power is turned on. Turn the power off, 19 6 01 B9 Press PAUSE button. (Note 7) then on again if the adjustment is retried. Check the flashing of strobe light. Switch setting: 1) FLASH ... ON 21 6 02 Check the data changes to “01”. 22 6 01 00 Press PAUSE button. 23 7 03 04 Press PAUSE button. 24 6 01 67 Press PAUSE button. Check the flashing of strobe light. 26 6 02 Check the data changes to “01”. Check that the data satisfies 27 F 64 the Y level data satisfied value. (Note 4) 28 0 03 02 Check the R-Y and B-Y level 29 1 data (Note 5) satisfies the specified value. Note 7: The adjustment data will be automatically input to page: F, address: 4D, 4E, 64 and 69 to 6B. Processing after Completing Adjustment: Order Page Address Data Procedure1003 002601 00 Press PAUSE button. 3 6 2C 004692 005693 00 Release the data setting 6 performed at step 2 . (Refer to page 5-14) 7 0 01 00 – 21 –,

DSC-S85 SECTION 6 REPAIR PARTS LIST

6-1. EXPLODED VIEWS 6-1-1. MAIN SECTION (Service manual page 6-1) DSC-S75 DSC-S85 Ref. No. Part No. Description Remark Ref. No. Part No. Description Remark 1 3-069-158-01 PROCESS, (M2) INTERIOR LOCK 1 3-719-381-01 SCREW (M2X4) 2 3-069-159-01 PROCESS, (M2) INTERIOR LOCK 2 3-069-159-11 PROCESS, (M2) INTERIOR LOCK 3 X-3951-668-1 HOLDER ASSY, BATTERY 3 X-3951-783-1 HOLDER ASSY, BATTERY 4 3-068-640-01 LID, BATTERY 4 3-068-640-11 LID, BATTERY 6-1-2. CABINET (FRONT) BLOCK ASSEMBLY (Service manual page 6-2) 79 ! : Points deleted portion. 77 78 ^ 75 85 SP901 # 79 79 not supplied DSC-S75 DSC-S85 Ref. No. Part No. Description Remark Ref. No. Part No. Description Remark 51 3-068-605-01 SCREW, FILTER 51 3-068-605-11 SCREW, FILTER 54 3-068-608-01 GRIP 54 3-068-608-11 GRIP 55 3-068-603-01 COVER, CABINET (FRONT) 55 3-068-603-11 COVER, CABINET (FRONT) 56 X-3951-665-1 CABINET (FRONT) ASSY 56 X-3951-781-1 CABINET (FRONT) ASSY 57 3-068-688-01 RETAINER, COVER SHAFT 57 3-068-688-11 RETAINER, COVER SHAFT 58 3-068-611-01 COVER, JACK 58 3-068-611-11 COVER, JACK 63 3-069-158-11 PROCESS, (M2) INTERIOR LOCK 63 3-719-381-01 SCREW (M2X4) 64 1-476-666-11 SWITCH BLOCK, CONTROL (MODE) 64 1-476-666-21 SWITCH BLOCK, CONTROL (MODE) 65 X-3951-667-1 CABINET ASSY, UPPER 65 X-3951-782-1 CABINET ASSY, UPPER 68 X-3951-670-1 GRILLE ASSY, MICROPHONE 68 X-3951-784-1 GRILLE ASSY, MICROPHONE 70 3-069-159-01 PROCESS, (M2) INTERIOR LOCK 70 3-069-159-11 PROCESS, (M2) INTERIOR LOCK 85 3-069-404-01 SPACER, SP 6-1-3. LENS BLOCK ASSEMBLY (Service manual page 6-3) DSC-S75 DSC-S85 Ref. No. Part No. Description Remark Ref. No. Part No. Description Remark 104 1-758-437-11 FILTER BLOCK, OPTICAL 104 1-758-618-11 FILTER BLOCK, OPTICAL 106 A-7074-888-A SY-68 BOARD, COMPLETE (SERVICE) 106 A-7096-838-A SY-68 BOARD, COMPLETE (SERVICE) IC151 A-7031-268-A CCD BLOCK ASSY (CCD IMAGER)(Note) IC151 A-7031-289-A CCD BLOCK ASSY (CCD IMAGER)(Note) 6-1-4. CABINET (REAR) BLOCK ASSEMBLY (Service manual page 6-4) DSC-S75 DSC-S85 Ref. No. Part No. Description Remark Ref. No. Part No. Description Remark 157 X-3951-671-1 CABINET (REAR) ASSY 157 X-3951-785-1 CABINET (REAR) ASSY 160 3-068-654-01 COVER, DC (IN) 160 3-068-654-11 COVER, DC (IN) – 22 –, 6-2. ELECTRICAL PARTS LIST Page DSC-S75 DSC-S85 Ref. No. Part No. Description Remark Ref. No. Part No. Description Remark ACCESSORIES ACCESSORIES ************ ************ 3-068-187-01 MANUAL, INSTRUCTION (JAPANESE) (J) 3-068-188-01 MANUAL, INSTRUCTION (JAPANESE) (J) 3-068-187-11 MANUAL, INSTRUCTION (ENGLISH) 3-068-188-11 MANUAL, INSTRUCTION (ENGLISH) (US, CND, AEP, UK, E, AUS, CN, HK, JE) (US, CND, AEP, UK, E, AUS, CN, HK, JE) 3-068-187-21 MANUAL, INSTRUCTION 3-068-188-21 MANUAL, INSTRUCTION (FRENCH, GERMAN) (CND, AEP, JE) (FRENCH, GERMAN) (CND, AEP, JE) 6-14 3-068-187-31 MANUAL, INSTRUCTION 3-068-188-31 MANUAL, INSTRUCTION (SPANISH, PORTUGUESE) (AEP, E, JE) (SPANISH, PORTUGUESE) (AEP, E, JE) 3-068-187-41 MANUAL, INSTRUCTION 3-068-188-41 MANUAL, INSTRUCTION (DUTCH, ITALIAN) (AEP) (DUTCH, ITALIAN) (AEP) 3-068-187-51 MANUAL, INSTRUCTION (TRADITIONAL 3-068-188-51 MANUAL, INSTRUCTION (TRADITIONAL CHINESE, SIMPLIFIED CHINESE) CHINESE, SIMPLIFIED CHINESE) (E, CN, HK, JE) (E, CN, HK, JE) 3-068-187-61 MANUAL, INSTRUCTION 3-068-188-61 MANUAL, INSTRUCTION (SWEDISH, RUSSIAN) (AEP, JE) (SWEDISH, RUSSIAN) (AEP, JE) 3-068-187-71 MANUAL, INSTRUCTION (ARABIC) (E) 3-068-188-71 MANUAL, INSTRUCTION (ARABIC) (E) 3-068-187-81 MANUAL, INSTRUCTION (KOREAN) 3-068-188-81 MANUAL, INSTRUCTION (KOREAN) (KR, JE) (KR, JE) – 23 –,

DSC-S85 Sony EMCS Co. Kohda TEC 2001H0500-19-929-905-32 © 2001. 8

– 24 – Published by PV Customer Center,

Reverse 992990532.pdf Revision History

S.M. Rev. Ver. Date History Contents issued 1.0 2001.06 Official Release — — S. M. correction: Page 3, Page 4, Page 5, Correction Page 6, Page 12, Page 14, 1.1 2001.08 Yes (C1 PV01-014) Page 16, Page 17, Page 18,]
15

Similar documents

SAFETY-RELATED COMPONENT WARNING!! ATTENTION AU COMPOSANT AYANT RAPPORT
DSC-S75 SERVICE MANUAL US Model Canadian Model Level 2 AEP Model UK Model E Model Ver 1.2 2001. 08 Hong Kong Model Australian Model Chinese Model Korea Model Tourist Model Japanese Model This service manual contains information for Japanese model as well. On the SY-68 board SY-68 board This service
DSC-T1 SERVICE MANUAL LEVEL 2 US Model Canadian Model UK Model Hong Kong Model Australian Model Korea Model Chinese Model Tourist Model Japanese Model
DSC-T1 SERVICE MANUAL LEVEL 2 US Model Ver 1.0 2003. 10 Canadian Model Revision History AEP Model UK Model How to use E Model Acrobat Reader Hong Kong Model Australian Model Korea Model Chinese Model Tourist Model Japanese Model Link SPECIFICATIONS BLOCK DIAGRAMS PRINTED WIRING BOARDS SERVICE NOTE F
DSC-T1 SERVICE MANUAL LEVEL 2 US Model Canadian Model UK Model Hong Kong Model Australian Model Korea Model Chinese Model Tourist Model Japanese Model
DSC-T1 SERVICE MANUAL LEVEL 2 US Model Ver 1.1 2004. 03 Canadian Model Revision History AEP Model UK Model How to use E Model Acrobat Reader Hong Kong Model Australian Model Korea Model Chinese Model Tourist Model Japanese Model Link SPECIFICATIONS BLOCK DIAGRAMS PRINTED WIRING BOARDS SERVICE NOTE F
DSC-T1 SERVICE MANUAL LEVEL 1 US Model Ver 1.2 2004. 03 Canadian Model UK Model E Model Hong Kong Model Australian Model Korea Model Chinese Model Tourist Model
DSC-T1 SERVICE MANUAL LEVEL 1 US Model Ver 1.2 2004. 03 Canadian Model Revision History AEP Model UK Model E Model Hong Kong Model Australian Model Korea Model Chinese Model Tourist Model Japanese Model Link SPECIFICATIONS SELF DIAGNOSIS FUNCTION • INSTRUCTION MANUAL is shown at the end of this docu
• Change of Automatic Adjustment Program • Change of Message for Destination Data
DSC-T100 Auto-ADJ SERVICE MANUAL Ver. 1.1 2007.04 SUPPLEMENT-1 File this supplement with the service manual. (DI07-003) • Change of Automatic Adjustment Program • Change of Message for Destination Data Write • Addition of [Read], [Save], and [Load] buttons to Angular Velocity Sensitivity Adjustment
CAUTION Danger of explosion if battery is incorrectly replaced.
DSC-T10 SERVICE MANUAL LEVEL 3 US Model Ver 1.1 2006.09 Canadian Model Revision History AEP Model UK Model How to use E Model Acrobat Reader Australian Model Hong Kong Model Chinese Model Internal memory Korea Model ON BOARD Argentine Model Brazilian Model Japanese Model Photo: Silver Tourist Model
SPECIFICATIONS Camera [Input and Output connectors] BC-CS3 battery charger
DSC-T10 SERVICE MANUAL LEVEL 2 US Model Ver 1.0 2006.07 Canadian Model Revision History AEP Model UK Model How to use E Model Acrobat Reader Australian Model Hong Kong Model Chinese Model Internal memory ON BOARD Korea Model Argentine Model Japanese Model Tourist Model Photo: Silver Link SPECIFICATI
SPECIFICATIONS Camera [Input and Output connectors] BC-CSG/BC-CSGB/BC-CSGC
DSC-T100 SERVICE MANUAL LEVEL 2 US Model Ver. 1.0 2007.02 Canadian Model Revision History AEP Model UK Model How to use E Model Acrobat Reader Australian Model Hong Kong Model Chinese Model Internal memory Korea Model ON BOARD Brazilian Model Japanese Model Tourist Model Photo: Silver Link SPECIFICA
WARNING To prevent fire or shock hazard, do
DSC-T11 SERVICE MANUAL LEVEL 1 Differences Manual DSC-T11 AEP Model UK Model E Model Ver 1.1 2004. 09 Hong Kong Model Australian Model Revision History Korea Model Chinese Model Tourist Model Japanese Model • This Service Manual shows only the difference from DSC-T1. Refer to the Service Manual Leve
WARNING To prevent fire or shock hazard, do
DSC-T11 SERVICE MANUAL LEVEL 1 Differences Manual DSC-T11 AEP Model UK Model E Model Ver 1.0 2004. 04 Hong Kong Model Australian Model Revision History Korea Model Chinese Model Tourist Model Japanese Model • This Service Manual shows only the difference from DSC-T1. Refer to the Service Manual Leve
SPECIFICATIONS Camera [Input and Output connectors] BC-CSG/BC-CSGB/BC-CSGC
DSC-T20/T25 SERVICE MANUAL LEVEL 2 US Model Ver 1.0 2007.03 Canadian Model Revision History AEP Model UK Model How to use E Model Acrobat Reader Australian Model Hong Kong Model Chinese Model Internal memory Korea Model ON BOARD Argentine Model Brazillian Model Japanese Model Photo: Silver Tourist M
Model information table
DSC-T20/T25 SERVICE MANUAL LEVEL 3 US Model Ver 1.0 2007.03 Canadian Model Revision History AEP Model UK Model How to use E Model Acrobat Reader Australian Model Hong Kong Model Chinese Model Internal memory Korea Model ON BOARD Argentine Model Brazillian Model Japanese Model Photo: Silver Tourist M
DSC-T3 SERVICE MANUAL LEVEL 2 DSC-T3
DSC-T3 SERVICE MANUAL LEVEL 2 DSC-T3 Ver 1.0 2004. 09 US Model AEP Model Revision History UK Model E Model Hong Kong Model Australian Model How to use Chinese Model Acrobat Reader Japanese Model Korea Model Tourist Model Link SPECIFICATIONS BLOCK DIAGRAMS PRINTED WIRING BOARDS SERVICE NOTE FRAME SCH
DSC-T3 SERVICE MANUAL LEVEL 1 DSC-T3 Ver 1.0 2004. 09 US Model Revision History UK Model Link SPECIFICATIONS ACCESSORIES SELF DIAGNOSIS FUNCTION
DSC-T3 SERVICE MANUAL LEVEL 1 DSC-T3 Ver 1.0 2004. 09 US Model AEP Model Revision History UK Model E Model Hong Kong Model Australian Model Chinese Model Japanese Model Korea Model Tourist Model Link SPECIFICATIONS ACCESSORIES SELF DIAGNOSIS FUNCTION • INSTRUCTION MANUAL is shown at the end of this
DSC-T3 SERVICE MANUAL LEVEL 2 DSC-T3
DSC-T3 SERVICE MANUAL LEVEL 2 DSC-T3 Ver 1.2 2005. 09 US Model AEP Model Revision History UK Model E Model Hong Kong Model Australian Model How to use Chinese Model Acrobat Reader Japanese Model Korea Model Tourist Model Link SPECIFICATIONS BLOCK DIAGRAMS PRINTED WIRING BOARDS SERVICE NOTE FRAME SCH
DSC-T3 SERVICE MANUAL LEVEL 2 DSC-T3
DSC-T3 SERVICE MANUAL LEVEL 2 DSC-T3 Ver 1.1 2005. 04 US Model AEP Model Revision History UK Model E Model Hong Kong Model Australian Model How to use Chinese Model Acrobat Reader Japanese Model Korea Model Tourist Model Link SPECIFICATIONS BLOCK DIAGRAMS PRINTED WIRING BOARDS SERVICE NOTE FRAME SCH
DSC-T3 SERVICE MANUAL LEVEL 1 DSC-T3 Ver 1.2 2005. 09 US Model Revision History AEP Model Link
DSC-T3 SERVICE MANUAL LEVEL 1 DSC-T3 Ver 1.2 2005. 09 US Model Canadian Model Revision History AEP Model UK Model E Model Hong Kong Model Australian Model Chinese Model Japanese Model Korea Model Tourist Model Link SPECIFICATIONS ACCESSORIES SELF DIAGNOSIS FUNCTION • INSTRUCTION MANUAL is shown at t
DSC-T3 SERVICE MANUAL LEVEL 1 DSC-T3 Ver 1.1 2005. 04 US Model Revision History UK Model Link SPECIFICATIONS ACCESSORIES SELF DIAGNOSIS FUNCTION
DSC-T3 SERVICE MANUAL LEVEL 1 DSC-T3 Ver 1.1 2005. 04 US Model AEP Model Revision History UK Model E Model Hong Kong Model Australian Model Chinese Model Japanese Model Korea Model Tourist Model Link SPECIFICATIONS ACCESSORIES SELF DIAGNOSIS FUNCTION • INSTRUCTION MANUAL is shown at the end of this
SPECIFICATIONS Camera [LCD screen] BC-CS3 battery charger
DSC-T30 SERVICE MANUAL LEVEL 2 US Model Ver 1.0 2006.03 Canadian Model Revision History AEP Model UK Model How to use E Model Acrobat Reader Australian Model Hong Kong Model Chinese Model Internal memory ON BOARD Korea Model Brazilian Model Japanese Model Tourist Model Photo: Silver Link SPECIFICATI
DSC-T5 SERVICE MANUAL LEVEL 1 US Model UK Model E Model Australian Model Hong Kong Model Chinese Model Korea Model Brazilian Model Japanese Model Tourist Model
DSC-T5 SERVICE MANUAL LEVEL 1 US Model Ver 1.2 2005.10 Canadian Model Revision History AEP Model UK Model E Model Australian Model Hong Kong Model Chinese Model Korea Model Brazilian Model Japanese Model Photo: Silver Tourist Model Link SPECIFICATIONS ACCESSORIES INSTRUCTION MANUAL SERVICE NOTE The
DSC-T5 SERVICE MANUAL LEVEL 2
DSC-T5 SERVICE MANUAL LEVEL 2 US Model Ver 1.2 2005.10 Canadian Model Revision History AEP Model UK Model How to use E Model Acrobat Reader Australian Model Hong Kong Model Internal memory Chinese Model ON BOARD Korea Model Brazilian Model Photo: Silver Japanese Model Tourist Model Link SPECIFICATIO
SPECIFICATIONS Camera [Input and Output connectors] BC-CS3 battery charger
DSC-T50 SERVICE MANUAL LEVEL 2 US Model Ver 1.0 2006.09 Canadian Model Revision History AEP Model UK Model E Model How to use Australian Model Acrobat Reader Hong Kong Model Chinese Model Korea Model Internal memory Argentine Model ON BOARD Brazilian Model Japanese Model Tourist Model Photo: Silver
DSC-T7 SERVICE MANUAL LEVEL 2 DSC-T7
DSC-T7 SERVICE MANUAL LEVEL 2 DSC-T7 Ver 1.1 2005. 06 US Model Canadian Model Revision History AEP Model UK Model E Model Hong Kong Model How to use Australian Model Acrobat Reader Chinese Model Japanese Model Brazilian Model Argentina Model Korea Model Tourist Model Link SPECIFICATIONS BLOCK DIAGRA
DSC-T7 SERVICE MANUAL LEVEL 1 DSC-T7 Ver 1.2 2005. 09 US Model
DSC-T7 SERVICE MANUAL LEVEL 1 DSC-T7 Ver 1.2 2005. 09 US Model Canadian Model Revision History AEP Model UK Model E Model Hong Kong Model Australian Model Chinese Model Japanese Model Brazilian Model Argentina Model Korea Model Tourist Model Link SPECIFICATIONS ACCESSORIES SELF DIAGNOSIS FUNCTION •
DSC-T7 SERVICE MANUAL LEVEL 2 DSC-T7
DSC-T7 SERVICE MANUAL LEVEL 2 DSC-T7 Ver 1.2 2005. 09 US Model Canadian Model Revision History AEP Model UK Model E Model Hong Kong Model How to use Australian Model Acrobat Reader Chinese Model Japanese Model Brazilian Model Argentina Model Korea Model Tourist Model Link SPECIFICATIONS BLOCK DIAGRA
DSC-T9 SERVICE MANUAL LEVEL 2
DSC-T9 SERVICE MANUAL LEVEL 2 US Model Ver 1.1 2005.12 Canadian Model Revision History AEP Model UK Model How to use E Model Acrobat Reader Australian Model Hong Kong Model Internal memory Chinese Model ON BOARD Korea Model Brazilian Model Japanese Model Photo: Silver Tourist Model Link SPECIFICATIO
DSC-T9 US Model SERVICE MANUAL Canadian Model AEP Model E Model Australian Model Hong Kong Model Chinese Model Korea Model Brazilian Model SUPPLEMENT-1 Japanese Model
DSC-T9 LEVEL 3 US Model SERVICE MANUAL Canadian Model AEP Model Ver 1.1 2005.12 UK Model E Model Australian Model Hong Kong Model Chinese Model Korea Model Brazilian Model SUPPLEMENT-1 Japanese Model Tourist Model File this supplement with the service manual. (PV05-072) • Addition of Brazilian Model
DSC-T9 SERVICE MANUAL Canadian Model SUPPLEMENT-1 Japanese Model
DSC-T9 LEVEL 2 US Model SERVICE MANUAL Canadian Model AEP Model Ver 1.1 2005.12 UK Model E Model Australian Model Hong Kong Model Chinese Model Korea Model Brazilian Model SUPPLEMENT-1 Japanese Model Tourist Model File this supplement with the service manual. (PV05-072) • Addition of Brazilian Model
DSC-T9 SERVICE MANUAL LEVEL 2
DSC-T9 SERVICE MANUAL LEVEL 2 US Model Ver 1.2 2006.06 Canadian Model Revision History AEP Model UK Model How to use E Model Acrobat Reader Australian Model Hong Kong Model Internal memory Chinese Model ON BOARD Korea Model Brazilian Model Japanese Model Photo: Silver Tourist Model Link SPECIFICATIO
If you have any questions about this product, you may call: Note:
DSC-U20 SERVICE MANUAL LEVEL 1 US Model Ver 1.0 2002. 10 Canadian Model Revision History AEP Model UK Model E Model Hong Kong Model Australian Model Chinese Model Korea model Photo: SILVER model Tourist Model Japanese Model Link SPECIFICATIONS SELF DIAGNOSIS FUNCTION ORNAMENTAL PARTS • INSTRUCTION M